An alarm rule says what raises an alarm, how serious it is, and who is told. Alarms here supplement your approved smoke, carbon monoxide and other safety systems. They never replace them.
Before you start
- You need the Manage IoT Alarms right. Without it you do not see the Alarms tab in the settings.
- To have people told in steps, create an escalation policy first, or create one from the rule. See Alarm Escalation Explained.
Create a rule
- Go to Settings → Devices (IoT) → Alarms → Rules and choose New rule.
- Give it a Rule name.
- Under What raises it, choose A reading is outside its limit, Something happens, A device stops responding or Raised by an automation. An automation decides when a rule of the last kind is raised: there is nothing to watch.
- For the other three, choose what the rule Applies to: One device, A room, A whole site, Every device of a type or Every device, then pick the device, room, site or type.
- Choose What to watch. For a reading, also choose how to Compare (goes above, goes below, becomes, stops being or changes at all) and the Value.
- Set the timings:
- For a reading: Reset margin means the alarm re-arms only once the reading is back past the limit by that much. Must last (minutes) raises the alarm only if the problem lasts that long. Clear after it has been normal for (minutes) stops an alarm from clearing and re-raising when a reading hovers at its limit.
- For a device that stops responding: Silent for (minutes).
- For something that happens: Clear by itself after (minutes), at least 1. The alarm still waits to be acknowledged.
- Choose the Severity: Critical (someone must respond now; it passes quiet hours), Major, Minor or Info. A new rule starts at Major.
- Write the Alarm title (needed, up to 200 characters) and, if you like, the Message and What to do about it (up to 500 characters each). To add a value such as the device's name, choose its chip under the title or message, for example
{{device.name}}. - Under Who is told, choose an escalation policy, or keep Built-in default. To make a policy now, choose New policy.
- Decide on Allow people to shelve this alarm, Watch only and Turned on. Watch only records the rule's alarms but tells nobody; it switches Turned on off, and the other way round.
- Choose Save rule.
Check it before you rely on it
- Choose Replay history to see how often the rule would have raised an alarm. Set From and To (it starts at the last 30 days) and choose Replay. It shows how many alarms it would have raised on how many devices, the busiest ten minutes, a chart of Alarms per day and how long a typical alarm lasted. "Nothing was sent. This is a replay of stored history." It uses your unsaved changes.
- Choose Preview who is told to see how many devices the rule matches and who each step reaches. It warns "Step 1 has nobody who can be told." when a step reaches nobody, and when someone cannot see all of the devices. A person who cannot see a device is not told about its alarms: give them access to the device.
Create rules from a template
- Open Devices (IoT) → Automations → Templates. This needs the Manage IoT Automations right too.
- Choose a template that includes an alarm rule, such as Freezer too warm, Smoke or carbon monoxide, Door left open or Device offline, and choose Choose.
- Fill in what it asks for, choose Review, check What this will create, then choose Review and create.
Everything a template makes starts turned off, so you can check it first. Turn a rule on with its switch in Settings → Devices (IoT) → Alarms → Rules.
On KamoMobile
KamoMobile has the same rule editor: open Devices (IoT), then Settings → Alarms → Rules, and choose New rule. You can also reach Alarm rules from the bottom of the Alarms screen.
Result
The rule is listed with what raises it, its severity, the number of devices it watches and how many alarms are open. Its switch turns it on and off. When it raises an alarm, the alarm appears on the Alarms tab and people are told as its policy says.
If it doesn't work
- "Another item already has this name." Choose a different name for the rule.
- "This rule matches no devices yet." The rule is saved, but it watches nothing. Check the devices you chose, and that they report what you picked.
- Turning a Critical rule off, or lowering its severity, asks for your password.
Good to know
Alarms depend on device vendors, networks and power, and can be delayed or fail. See IoT Is Not a Safety System.
บทความ ที่ เกี่ยว ข้อง
มัคคุเทศก์ คน อื่น ๆ ที่ ตอบ คํา ถาม ที่ อยู่ ใกล้ ๆ คน นี้.
เรื่อง ราว ชีวิต จริง
การวางเพลิงทําให้สัญญาณดังถึงใครบางคน ถ้าไม่มีใครยอมรับ ขั้นตอนถัดไปจะบอกผู้คน และอื่น ๆ นโยบายคือรายการของขั้นตอน นโยบายการเลื่อนขั้นมีถึง 8 ขั้น แต่ ละ ขั้น บอก ว่า เมื่อ ไร จะ บอก และ ทํา อย่าง ไร.…
วิธี เตือน ล่วง หน้า
การ ตื่น ตัว ต่อ สัญญาณ เตือน บอก ทุก คน ว่า คุณ ได้ เห็น แล้ว และ กําลัง รับมือ อยู่. นอก จาก นั้น มัน ยัง ทํา ให้ สัญญาณ เตือน เพิ่ม ขึ้น จน ถึง ขั้น ต่อ ไป ของ นโยบาย. ก่อนจะเริ่ม คุณจําเป็นต้องมี ICT…
วิธี สร้าง อัตโนมัติ
อัตโนมัติทํางานตามขั้นตอนของมันเอง เมื่อมีอะไรเกิดขึ้น: การอ่านข้ามขีด จํากัด, อุปกรณ์รายงานเหตุการณ์ หรือเวลาออฟไลน์ เวลาที่มาถึง, ดวงอาทิตย์ขึ้นหรือตั้งค่า, โหมดการเปลี่ยนแปลงของเว็บไซต์ หรือการเปลี่ยนสัญญาณเตือน…
IoT Is Not a Safety System
IoT Devices is not an alarm-monitoring, emergency-response or life-safety system. This article says what that means in practice. What not to rely on it for Protecting life, health or property. Detecting or responding to…
วิธี ทดสอบ การ ปรับ ตัว ให้ เข้า กับ กิจกรรม ใน อดีต
ก่อน ทํา การ อัตโนมัติ ให้ เปิด ดู ประวัติ ที่ เก็บ ไว้ เพื่อ ดู ว่า มัน จะ วิ่ง บ่อย แค่ ไหน. ไม่ มี การ ส่ง หรือ เปลี่ยน แปลง: มัน เป็น การ บันทึก ประวัติศาสตร์ ที่ เก็บ รักษา ไว้. ก่อนจะเริ่ม…
Site Modes Explained
A site mode is the state a site is in. Every site starts in Occupied. The built-in modes are Occupied, Away, Night and Holiday, and your organization can add its own. Automations can read a site's mode and change it.…